  • Chapter 3: Protruding objects - United States Access Board
    Free-standing objects with leading edges 27″ to 80″ high that are mounted on posts or pylons cannot protrude more than 12″ into circulation paths The 12″ limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)
  • Chapter 3: Protruding Objects - United States Access Board
    Free-standing objects with leading edges 27” to 80” high that are mounted on posts or pylons cannot protrude more than 12” into circulation paths The 12” limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)
  • ADA Protruding Objects - ADA Compliance
    4 4 Protruding Objects Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100 mm) into walks, halls, corridors, passageways, or aisles
  • Protruding Objects | UpCodes
    Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path EXCEPTION: Handrails shall be permitted to protrude 4 1 2 inches (115 mm) maximum Advisory 307 2 Protrusion Limits
  • Protruding Objects - Corada
    Free-standing objects with leading edges 27” to 80” high that are mounted on posts or pylons cannot protrude more than 12” into circulation paths The 12” limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)
  • ADA Protrusion Limits | MPM Customer Portal
    Free-standing objects with leading edges 27″ to 80″ high that are mounted on posts or pylons cannot protrude more than 12″ into circulation paths The 12″ limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)
  • 307 Protruding Objects - ADA Compliance
    Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground
  • Chapter 3: Protruding Objects - United States Access Board
    Fixed barriers, such as guardrails, are required where the vertical clearance is less than 80” such as at open stairways and along sloped or curved walls Barriers must have leading edges no higher than 27” so that they are within cane sweep
  • 307 Protruding Objects - Mypdh. engineer
    Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or obstruction shall be 27 inches (685 mm) maximum or 80 inches (2030 mm) minimum above the finish floor or ground
  • ADA Inspections Nationwide, LLC — ADA Compliancy
    Protruding objects are common discrepancies in facilities where the American with Disabilities Act (ADA) Standards apply This article will discuss the technical requirements for protruding objects The 2010 ADA Standards that apply the most to protruding objects are 204 and 307