  • square wave -- gt;sine using passive bandpass filter | Eng-Tips
    Hi, I'm designing a circuit that will take a square wave generated by a microprocessor and feeds it through a bandpass filter to get a sine wave The application will be to provide a tone for morse code to a handheld ham radio on board a small satellite Right now im considering remaining
  • PWM Frequency for DC Motor Control - Eng-Tips
    As a practical matter, 15 to 20 kHz is the usual switching frequency for motor drives This is so that audable noise is not a problem The ripple current will also be low for common values of motor inductances (current ripple increases the motor heating)
  • Transformer S11 parameter analysis | Eng-Tips
    Marker 1 is at 100 KHz and shows my expected inductance of 106 uH (67 jOhm) That make sense At frequencies above that the inductance increases, with Marker 2 showing 6 4K at 1 7 MHz (106 uH is 1 1K jOhm) I’m assuming this is a change in the magnetic core properties with frequency Marker 2 at 1 7 MHz appears to be the self-resonant frequency (SRF), as I cross from positive (inductive) to
  • Plastic material which is permeable for IR (infra red) signals
    As mentioned in subject - Can anyone tell me what plastic material shall I use for device with IR antena (reciever)? thx in advance
  • What is minimum motor length cable to install a pure sine wave filter . . .
    8 Set switching frequency somewhere between 3 to 5 kHz 9 NOTE: Usual cable length tables in VFD documentation is not applicable to submersible pump application 10 NOTE: Sine wave filters between drive output and motor terminals IS REQUIRED Standard dv dt filter is not sufficient (due primarily to high frequency switching and length of
  • Required contact area for electrical connection - Eng-Tips
    Looking for some sparky knowledge here I'm designing some test equipment and need to make sure I have enough contact area to prevent heating a threaded connection beyond the point where it can be reused We will be running 1000V and 1000A through the connection The real trick is the duration
  • Impedance Measurement of a DC-DC power supply | Eng-Tips
    A clamp-on current probe usually has a limited frequency range, but there are Fluke DC - several hundred kHz clamps And Chauvin-Arnoux and Tektronix going well beyond 1 MHz
  • Rewinding of submersible pump motor - Eng-Tips
    4) The switching frequency (for the drive) should be set somewhere between 3 and 5 kHz - note that in the OP's original post, it was indicated this had been set to 2 5 kHz 5) According to the drive manufacturer documentation, A SINE WAVE FILTER IS REQUIRED - REGARDLESS OF CABLE DISTANCE BETWEEN DRIVE AND MOTOR
  • Fast switching SSR SPDT (Solid state Single-Pole-Double Throw) Relay
    Good day Noble Minds, I need a fast switching SPDT relay(not less than 1Khz) to implement the circuit below Both S1 switches will close to terminal 1, when both S2 switches close to terminal 2 and vice versa Your recommendation of any available module in the market will be highly
  • how to interface a differential op-amp to a single ended output
    I would like to have a regular op-amp (single ended) input driven via differential outputs from a differential op-amp I assume this will be better than going to a single ended configuration right after the diff op-amp (typical configuration) The question is how to best interface the ad8137 in